AQUATEX PRODUCTS

Stormwater detention in Kenya — BlockTech

Review BlockTech for Kenyan stormwater detention or infiltration projects. Prepare county, drainage, ground and maintenance inputs for a project quote.

BlockTech modular element
BlockTech modular element

A modular structure with a project-specific enclosure

BlockTech uses connected polymer elements to create underground storage. The surrounding enclosure and outlet arrangement determine whether water is released gradually, retained or infiltrated into the soil.

Prepare a modular detention request around the Kenyan site's catchment and receiving drain. Identify county coordination, discharge or infiltration evidence, construction access and the long-term owner before comparing a BlockTech supply proposal.

How it works

  1. Inflow
  2. Storage
  3. Controlled release, retention or infiltration
Conceptual flow; not a construction drawing.

A modular structure with a project-specific enclosure

The catalogue identifies four elements: main module, fixator, side panel and sectional lid. Modules form the reservoir structure; perimeter elements support the enclosure. The selected layout must accommodate inlets, outlets and inspection access.

Three functions, different arrangements

Attenuation temporarily stores runoff and releases it through a controlled outlet. Retention keeps water for a defined purpose. Infiltration releases suitable water into the ground. The catalogue illustrates permeable geotextile for infiltration and a geotextile–geomembrane–geotextile enclosure for storage; the enclosure, seams and outlet are specified for the project.

Components and supply scope

Main modules, fixators, side panels and sectional lids form the described structure. Enclosure materials, inspection access, inlet/outlet connections, pretreatment and flow controls must be identified in the proposal; do not assume all are included in a module price.

Installation and maintenance

The catalogue sequence covers base preparation, enclosure, modules and fixators, perimeter elements, inspection points, enclosure checks and backfill. It is an overview, not a site instruction. Loading, cover, ground and groundwater require design checks. Plan sediment management, inspection and cleaning access before installation.

Link detention to the Kenyan site's receiving system

Record county, site, receiving drain, appointed designer and the criteria adopted for the works. Send catchment, rainfall basis, required storage, outlet conditions and exceedance route together. Separate drainage discharge from any proposed storage for later use. For infiltration, include the actual ground investigation, groundwater and water-quality evidence rather than presuming a modular layout establishes suitability.

Keep construction and maintenance practical

Include site access, utility conflicts, surface use, construction sequence and maintenance ownership in the request. State the destination and separate product supply, transport, outlet equipment, pretreatment and civil works. Identify which county, asset-owner or water-resource questions the appointed team still needs to resolve for the actual site. Ask for the selected configuration's documents and the information required for a usable operating record.

Documents

These product information packs describe construction, functions, interfaces and source reference data. They are not certificates or approved installation instructions.

BlockTech — Product information pack

How it works · Technical information · Supply and interfaces · Installation and maintenance

Language
English
Version
1.1
Prepared
2026-11-02

Main module: geometry and mass

Values apply to the main module, not a complete reservoir or its accessories. The module is a polymer element.

Length (mm)1000 ± 2
Width (mm)500 ± 2
Height (mm)250 ± 2
Module mass (kg)5.4 ± 0.2
Nominal external volume (m³, calculated)0.125
1000 ± 2 mm500 ± 2 mm250 ± 2 mm
Schematic of the nominal external module envelope, not a construction drawing. Internal geometry and connection details are not shown.

Nominal external-envelope calculation

(1000 / 1000) × (500 / 1000) × (250 / 1000) = 0.125 m³

Water capacity of the assembled reservoir

The source states a 95% working-volume fraction for the assembled reservoir. It does not give a net water capacity for an individual module or every layout. The selected reservoir capacity depends on the arrangement and operating levels; 0.125 m³ is the external geometric envelope, not useful water volume.

Optional project details

  • Location and project stage
  • Water source and intended use
  • Known volume (m³), flow (m³/h) and levels
  • Ground, groundwater, loading and access where known
  • Required supply scope; unknown values may be left blank

Questions and answers

Are attenuation, retention and infiltration the same?

No. Attenuation delays discharge, retention holds water for a purpose, and infiltration returns water to the soil. The enclosure and outlets must match the selected function.

Is infiltration suitable for every site?

No. Soil, groundwater, water quality and the applicable drainage requirements must support it.

Is a traffic load rating stated here?

No. A location under parking does not establish allowable loading or cover. Use evidence and design checks for the selected configuration.

What does the supply include?

The proposal must identify modules, locks, perimeter elements, enclosure, access, connections and any pretreatment or outlet controls, with exclusions.