AQUATEX PRODUCTS

Modular stormwater attenuation tanks in the UAE — BlockTech

Explore BlockTech stormwater attenuation and infiltration configurations for UAE projects. Prepare drainage, site and maintenance inputs for a project quote.

BlockTech modular element
BlockTech modular element

A modular structure with a project-specific enclosure

BlockTech uses connected polymer elements to create underground storage. The surrounding enclosure and outlet arrangement determine whether water is released gradually, retained or infiltrated into the soil.

Turn the UAE site's drainage assessment into a defined BlockTech supply request. Connect the receiving-system conditions to the proposed modular arrangement, then identify procurement, construction and maintenance interfaces before comparing a configuration.

How it works

  1. Inflow
  2. Storage
  3. Controlled release, retention or infiltration
Conceptual flow; not a construction drawing.

A modular structure with a project-specific enclosure

The catalogue identifies four elements: main module, fixator, side panel and sectional lid. Modules form the reservoir structure; perimeter elements support the enclosure. The selected layout must accommodate inlets, outlets and inspection access.

Three functions, different arrangements

Attenuation temporarily stores runoff and releases it through a controlled outlet. Retention keeps water for a defined purpose. Infiltration releases suitable water into the ground. The catalogue illustrates permeable geotextile for infiltration and a geotextile–geomembrane–geotextile enclosure for storage; the enclosure, seams and outlet are specified for the project.

Components and supply scope

Main modules, fixators, side panels and sectional lids form the described structure. Enclosure materials, inspection access, inlet/outlet connections, pretreatment and flow controls must be identified in the proposal; do not assume all are included in a module price.

Installation and maintenance

The catalogue sequence covers base preparation, enclosure, modules and fixators, perimeter elements, inspection points, enclosure checks and backfill. It is an overview, not a site instruction. Loading, cover, ground and groundwater require design checks. Plan sediment management, inspection and cleaning access before installation.

Connect the UAE drainage brief to the receiving system

Record the emirate, site, appointed drainage designer and the authority or asset owner responsible for the receiving system. Share the drainage-report reference, catchment, adopted rainfall and event criteria, required storage, discharge conditions and exceedance route. Identify outlet levels, controls and downstream constraints with the designer. Any infiltration proposal needs its own ground, groundwater and water-quality evidence and a decision for the actual site.

Define a UAE supply and operating scope

Name the delivery destination and procurement stage, and separate modular supply from outlet controls, pretreatment, transport and civil works. Include construction access, utilities, surface loading and planned maintenance ownership in the inquiry. Ask for the proposed configuration, interfaces, applicable installation documents and unresolved inputs. Agree the records needed for inspection and handover with the asset owner; do not infer a delivery commitment or product acceptance from a general project page.

Documents

These product information packs describe construction, functions, interfaces and source reference data. They are not certificates or approved installation instructions.

BlockTech — Product information pack

How it works · Technical information · Supply and interfaces · Installation and maintenance

Language
English
Version
1.1
Prepared
2026-11-02

Main module: geometry and mass

Values apply to the main module, not a complete reservoir or its accessories. The module is a polymer element.

Length (mm)1000 ± 2
Width (mm)500 ± 2
Height (mm)250 ± 2
Module mass (kg)5.4 ± 0.2
Nominal external volume (m³, calculated)0.125
1000 ± 2 mm500 ± 2 mm250 ± 2 mm
Schematic of the nominal external module envelope, not a construction drawing. Internal geometry and connection details are not shown.

Nominal external-envelope calculation

(1000 / 1000) × (500 / 1000) × (250 / 1000) = 0.125 m³

Water capacity of the assembled reservoir

The source states a 95% working-volume fraction for the assembled reservoir. It does not give a net water capacity for an individual module or every layout. The selected reservoir capacity depends on the arrangement and operating levels; 0.125 m³ is the external geometric envelope, not useful water volume.

Optional project details

  • Location and project stage
  • Water source and intended use
  • Known volume (m³), flow (m³/h) and levels
  • Ground, groundwater, loading and access where known
  • Required supply scope; unknown values may be left blank

Questions and answers

Are attenuation, retention and infiltration the same?

No. Attenuation delays discharge, retention holds water for a purpose, and infiltration returns water to the soil. The enclosure and outlets must match the selected function.

Is infiltration suitable for every site?

No. Soil, groundwater, water quality and the applicable drainage requirements must support it.

Is a traffic load rating stated here?

No. A location under parking does not establish allowable loading or cover. Use evidence and design checks for the selected configuration.

What does the supply include?

The proposal must identify modules, locks, perimeter elements, enclosure, access, connections and any pretreatment or outlet controls, with exclusions.

Blank project brief, revision 2026-10-07. Record values, units, sources and open items; this worksheet contains no product specifications.

Download the editable project-input worksheet (CSV)