AQUATEX PRODUCTS

BlockTech geocellular stormwater system for US projects

Review BlockTech geocellular systems for US detention and infiltration projects. Coordinate the engineer's brief, installation documents and supply scope.

BlockTech modular element
BlockTech modular element

Follow the project duty from site evidence to product review. Detention, infiltration and water reuse require different inputs.

A modular structure with a project-specific enclosure

BlockTech uses connected polymer elements to create underground storage. The surrounding enclosure and outlet arrangement determine whether water is released gradually, retained or infiltrated into the soil.

Prepare a US BlockTech product request from the engineer's detention or infiltration brief. Use the dedicated detention solution route for the hydraulic task, then specify modular supply, installation documents and operating interfaces for the proposed arrangement.

How it works

  1. Inflow
  2. Storage
  3. Controlled release, retention or infiltration
Conceptual flow; not a construction drawing.

A modular structure with a project-specific enclosure

The catalogue identifies four elements: main module, fixator, side panel and sectional lid. Modules form the reservoir structure; perimeter elements support the enclosure. The selected layout must accommodate inlets, outlets and inspection access.

Three functions, different arrangements

Attenuation temporarily stores runoff and releases it through a controlled outlet. Retention keeps water for a defined purpose. Infiltration releases suitable water into the ground. The catalogue illustrates permeable geotextile for infiltration and a geotextile–geomembrane–geotextile enclosure for storage; the enclosure, seams and outlet are specified for the project.

Components and supply scope

Main modules, fixators, side panels and sectional lids form the described structure. Enclosure materials, inspection access, inlet/outlet connections, pretreatment and flow controls must be identified in the proposal; do not assume all are included in a module price.

Installation and maintenance

The catalogue sequence covers base preparation, enclosure, modules and fixators, perimeter elements, inspection points, enclosure checks and backfill. It is an overview, not a site instruction. Loading, cover, ground and groundwater require design checks. Plan sediment management, inspection and cleaning access before installation.

Use the US detention criteria adopted for the project

Describe an underground stormwater detention requirement using the site's drainage assessment, including contributing areas, design events, inflow hydrograph, allowable discharge and tailwater. State the engineer's required storage and the proposed outlet or emergency overflow arrangement. Identify the responsible state or local authority and the criteria adopted for the site. Infiltration needs a separate field investigation and acceptance decision; a map or product name cannot settle it.

Turn the detention brief into a supply request

Name the project stage, delivery destination, engineer and asset owner. Separate modular supply from outlet controls, pretreatment, excavation, civil works and the final drainage design. Request current configuration, installation, inspection and maintenance documents for the arrangement being considered. Keep temporary construction loading, installed-layout records and operating responsibilities visible in the procurement package alongside permanent conditions.

Documents

These product information packs describe construction, functions, interfaces and source reference data. They are not certificates or approved installation instructions.

BlockTech — Product information pack

How it works · Technical information · Supply and interfaces · Installation and maintenance

Language
English
Version
1.1
Prepared
2026-11-02

Main module: geometry and mass

Values apply to the main module, not a complete reservoir or its accessories. The module is a polymer element.

Length (mm)1000 ± 2
Width (mm)500 ± 2
Height (mm)250 ± 2
Module mass (kg)5.4 ± 0.2
Nominal external volume (m³, calculated)0.125
1000 ± 2 mm500 ± 2 mm250 ± 2 mm
Schematic of the nominal external module envelope, not a construction drawing. Internal geometry and connection details are not shown.

Nominal external-envelope calculation

(1000 / 1000) × (500 / 1000) × (250 / 1000) = 0.125 m³

Water capacity of the assembled reservoir

The source states a 95% working-volume fraction for the assembled reservoir. It does not give a net water capacity for an individual module or every layout. The selected reservoir capacity depends on the arrangement and operating levels; 0.125 m³ is the external geometric envelope, not useful water volume.

Optional project details

  • Location and project stage
  • Water source and intended use
  • Known volume (m³), flow (m³/h) and levels
  • Ground, groundwater, loading and access where known
  • Required supply scope; unknown values may be left blank

Questions and answers

Are attenuation, retention and infiltration the same?

No. Attenuation delays discharge, retention holds water for a purpose, and infiltration returns water to the soil. The enclosure and outlets must match the selected function.

Is infiltration suitable for every site?

No. Soil, groundwater, water quality and the applicable drainage requirements must support it.

Is a traffic load rating stated here?

No. A location under parking does not establish allowable loading or cover. Use evidence and design checks for the selected configuration.

What does the supply include?

The proposal must identify modules, locks, perimeter elements, enclosure, access, connections and any pretreatment or outlet controls, with exclusions.

Blank project brief, revision 2026-10-07. Record values, units, sources and open items; this worksheet contains no product specifications.

Download the editable project-input worksheet (CSV)

Public references for the project location